European Journal of Prosthodontics and Restorative Dentistry
- Cover Date:
- September 2012
- Print ISSN:
- 0965-7452
- Vol:
- 20
- Issue:
- 3
Comparative Evaluation of Effect of Polymerizable and non-Polymerizable Desensitizing Agents on Crown-Retentive-Strength of Zinc-Phosphate, Glass-Ionomer and Compomer Cements
Abstract - The Purpose of this study was to evaluate the effect of polymerizable and non-polymerizable dentine desensitizers on retention of complete cast crowns cemented with three different types of cements. Freshly extracted human molars (n=90) were prepared for standardized crown preparation (6-degree taper, 4-mm height). The axial surface area of each preparation was determined and specimens were distributed equally among groups (n=10). Dentine desensitizers, cementing agents, glass ionomer cement and compomer cement. Teeth were prepared and individual castings were made using high noble porcelain-metal alloy. Castings were cemented, thermo-cycled and removed along the path of insertion using a universal testing machine. Tooth surface as well as inner surface of the casting was examined and nature of cement failure was determined. Compomer cement exhibited the highest retentive strength and all dentine treatments resulted in significantly different retentive values. Zinc phosphate was the least retentive. Crown retentive values of Compomer cement were improved with Prime & Bond NT and Gluma Desensitizer. Retentive values of zinc phosphate cement with Prime & Bond NT were decreased and not affected with Gluma Desensitizer. Retentive values of Glass ionomer cement were not affected by any of the desensitizers used in the study.
KEY WORDS: desensitizer agents, crown retention
- Article Price
- £15.00
- Institution Article Price
- £
- Page Start
- 102
- Page End
- 112
- Authors
- P.G. Patil, R.D. Parkhedkar, S.P. Patil, H.S. Bhowmik
Articles from this issue
- Title
- Pg. Start
- Pg. End
- Forced Eruption Without Orthodontic Brackets Using Fiber Reinforced Composite Prostheses: A Case Report.
- 98
- 101
- Comparative Evaluation of Effect of Polymerizable and non-Polymerizable Desensitizing Agents on Crown-Retentive-Strength of Zinc-Phosphate, Glass-Ionomer and Compomer Cements
- 102
- 112
- Prevalence of Temporomandibular Disorders’ Signs and Symptoms and Chewing Ability in Patients with Prosthodontic Prostheses
- 111
- 120
- Effect of Surface Treatments on the Bond Strengths of Facing Composite Resins to Zirconia Copings
- 122
- 129
- The Effect of Monomer/Polymer Mixing Ratio,Time Between Mixing and Packing of Heat Cured Acrylic Resin Denture Base Material and Bond Assisting Agents on the Bond Strength to Acrylic Resin Denture T eeth
- 131
- 134
- Influence of Nd:YAG or Er:YAG Laser Surface Treatment on Microtensile Bond Strength of Indirect Resin Composites to Resin Cement Lasers Surface Treatment of Indirect Resin Composites
- 135
- 140